[ENG] IEC 60079- Electrical Apparatus for Explosive Gas Atmosphere

IEC 60079-      ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES

Part 0     Ed. 6.0/2011      General requirements
Part 1     Ed. 6.0/2007      Equipment protection by flameproof enclosures “d”
Part 2     Ed. 5.0/2007      Equipment protection by pressurized enclosures “p”
Part 3     Ed. 1.0/1963      Spark test apparatus for intrinsically safe circuits (Withdrawn)
Part 4     Ed. 1.0/1966      Method of test for ignition temperature (Withdrawn)
Part 5     Ed. 3.0/2007      Equipment protection by powder filling “q”
Part 6     Ed 3.0/2007       Equipment protection by oil immersion “o”
Part 7     Ed. 4.0/2006      Equipment protection by increased safety “e”
Part 8     Ed. 1.0/1969      Classification of maximum surface temperature (Withdrawn)
Part 9     Ed. 1.0/1979      Marking (Withdrawn)
Part 10   Ed. 1.0/2008      Classification of hazardous areas
10-1                        Explosive gas atmospheres
10-2                        Combustible dust atmospheres
Part 11   Ed. 6.0/2011      Equipment protection by intrinsic safety “i”
Part 12   Ed. 1.0/1978      Classification of mixtures of gases of vapours with air according to their maximum experimental safe gaps and minimum igniting currents (Withdrawn)
Part 13   Ed. 1.0/2010      Equipment protection by pressurized room “p”
Part 14   Ed. 4.0/2007      Electrical installations design, selection and erection
Part 15   Ed. 4.0/2010      Equipment protection by type of protection “n”
Part 16   Ed. 1.0/1990      Artificial ventilation for the protection of analyzer(s) houses
Part 17   Ed. 4.0/2007      Electrical installations inspection and maintenance
Part 18   Ed. 3.0/2009      Equipment protection by encapsulation “m”
Part 19   Ed. 3.0/2010      Equipment repair, overhaul and reclamation
Part 20   Ed. 1.0/2010      Material characteristics for gas and vapour classification – Test methods and data
Part 21                             N/A
Part 22                             N/A
Part 23                             N/A
Part 24                             N/A
Part 25   Ed. 2.0/2010      Intrinsically safe electrical systems
Part 26   Ed. 2.0/2006      Special requirements for construction test and marking of zone 0 electrical apparatus
Part 27   Ed. 2.0/2008      Fieldbus intrinsically safe concept (FISCO) (Withdrawn)
Part 28   Ed. 1.0/2006      Protection of equipment and transmission systems using optical radiation
Part 29   Ed. 1.0/2007      Gas detectors
Part 30   Ed. 1.0/2007      Electrical resistance trace heating
Part 31   Ed. 1.0/2008      Equipment dust ignition protection by enclosure “t”
Part 32   Ed. 1.0/ –           Electrostatic Hazards – Guidance (DRAFT)
Part 33   Ed. 1.0/2012      Equipment protection by special protection ‘s’
Part 34                             N/A
Part 35   Ed .1.0/2011      Caplights for use in mines susceptible to firedamp

Note that the 60079 series of standards will gradually address dust hazards as well as gas/vapour hazards. The standard number will have an additional suffix 1 or 2. Thus, for example, 61241-14 (see below) will be replaced by 60079-14-2 [installation for equipment in dust hazards], with 60079-14-1 dealing with installations in gas/vapour hazards.


(Note. BLACK = Usually used, RED = Withdrawn/Not Applicable, BLUE = Rarely used



(Gathered from many sources in the internet)